1.
Clin Biochem ; : 110761, 2024 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-38565341

RESUMO

OBJECTIVES: Some therapeutic monoclonal antibodies, like daratumumab and elotuzumab, produce interfering monoclonal bands on serum protein electrophoresis (SPEP) and immunofixation electrophoresis (IFE). Whether other common therapeutic antibodies also produce interference has not been systematically evaluated. DESIGN AND METHODS: SPEP/IFE from patients receiving isatuximab (48 patients), belantamab mafodotin (BM; 41), and denosumab (41) were retrospectively reviewed for therapeutic antibody interference. Cases exhibiting isatuximab interference were quantified and the maximum duration of isatuximab effect was evaluated. To characterize band position, neat human serum was spiked with BM or denosumab at supratherapeutic concentrations. Band migration patterns were compared on SPEP and IFE, with band position expressed relative to other constant protein fractions. RESULTS: Isatuximab-induced IFE interference was common (81.3 % of evaluated patients) with a maximum observed duration of 8 weeks. 10.4 % of isatuximab patients had IgG-kappa monoclonal gammopathies that co-migrated with the drug; this subset could benefit from HYDRASHIFT 2/4 isatuximab testing. 8.3 % of IFE cases were negative for an isatuximab band but showed large, endogenous M-spikes migrating elsewhere. All patients in this group expired within 1 year of this finding. We hypothesize that an inability to detect isatuximab in this setting corresponds to a large residual myeloma burden that reduces isatuximab serum concentration. This observation may serve as a negative prognostic factor. Spiking studies demonstrated that BM and denosumab produce interference in vitro, but sustained interference was not observed in >40 treated patients. CONCLUSIONS: Therapeutic antibody interference in patients receiving isatuximab is common, and can persist for at least 8 weeks after administration. >10 % of patients receiving isatuximab may benefit from HYDRASHIFT testing post-therapy. In contrast, BM and denosumab fail to produce sustained interference in treated patients.

2.
Chembiochem ; : e202400108, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38567504

RESUMO

Detailed insights into protein structure/function relationships require robust characterization methodologies. Free-solution capillary electrophoresis (CE) is a unique separation technique which is sensitive to the conformation and/or composition of proteins, and therefore provides information on the heterogeneity of these properties. Three unrelated, conformationally/compositionally-altered proteins were separated by CE. An electrophoretic mobility distribution was determined for each protein along with its conformational and/or compositional heterogeneity. CE results were compared with molar mass distributions obtained from size-exclusion chromatography coupled to light scattering (SEC-MALS). Bovine serum albumin oligomers and two monomeric species were separated, highlighting variations in conformational/compositional heterogeneity among the oligomers. Analysis of yeast alcohol dehydrogenase resolved two monomeric conformers and various tetrameric species, illustrating the impact of zinc ion removal and disulfide bond reduction on the protein's heterogeneity. The apo (calcium-free) and holo forms of bovine α-lactalbumin were separated and differences in the species' heterogeneity was measured; by contrast, the SEC-MALS profiles were identical. Comparative analysis of these structurally unrelated proteins provided novel insights into the interplay between molar mass and conformational/compositional heterogeneity. Overall, this study expands the utility of CE by demonstrating its capacity to discern protein species and their heterogeneity, properties which are not readily accessible by other analytical techniques.

3.
Foodborne Pathog Dis ; 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38557159

RESUMO

The urgent need for comprehensive and systematic analyses of Shigella as the key pathogen led us to meticulously explore the epidemiology and molecular attributes of Shigella isolates. Accordingly, we procured 24 isolates (10 from Xinjiang and 14 from Wuhan, China) and performed serotype identification and antimicrobial susceptibility testing. Resistance gene detection and homology analysis by polymerase chain reaction and pulsed-field gel electrophoresis (PFGE), respectively, were performed for genetic diversity analysis. All isolates were identified as Shigella flexneri, with 70% (35.4-91.9%) and 30% (8.1-64.6%) of the Xinjiang isolates and 85.7% (56.2-97.5%) and 14.3% (2/14, 2.5-43.9%) of the Wuhan isolates belonging to serotype 2a and serotype 2b, respectively. All isolates displayed resistance to at least two antibiotics and complete resistance to ampicillin. Multidrug resistance (MDR) was recorded in 70.8% (48.8-86.6%) of isolates, with Xinjiang isolates exhibiting relatively higher resistance to ampicillin-sulbactam, piperacillin, ceftriaxone, and aztreonam. Conversely, Wuhan isolates displayed higher MDR and resistance to tetracycline, ciprofloxacin, levofloxacin, and cefepime relative to Xinjiang isolates. Molecular scrutiny of antibiotic-resistance determinants revealed that blaTEM was the main mechanism of ampicillin resistance, blaCTX-M was the main gene for resistance to third- and fourth-generation cephalosporins, and tetB was the predominant gene associated with tetracycline resistance. Four Xinjiang and seven Wuhan isolates shared T1-clone types (>85%), and two Xinjiang and one Wuhan isolates were derived from the T6 clone with a high similarity of 87%. Six PFGE patterns (T1, T2, T5, T6-3, T8, and T10) of S. flexneri were associated with MDR. Thus, there is a critical need for robust surveillance and control strategies in managing Shigella infections, along with the development of targeted interventions and antimicrobial stewardship programs tailored to the distinct characteristics of Shigella isolates in different regions of China.

4.
Methods Mol Biol ; 2797: 337-350, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38570471

RESUMO

Isogenic H/N/KRAS-less mouse embryonic fibroblast (MEF) cell lines have been developed to assist in cell-based assays of RAS inhibitors. The quality control assessment of a panel of these isogenic MEFs is described here, with a focus on ensuring the proper insertion of the desired mutant RAS transgene, a determination of gene copy number, and an investigation of potential off-target mutations which could lead to phenotypes which are undesired in downstream experiments. Using this suite of quality control tools, a MEF cell line can be readily validated, and researchers can be assured of the rationale for an observed phenotype.


Assuntos
Fibroblastos , Proteínas Proto-Oncogênicas p21(ras) , Animais , Camundongos , Proteínas Proto-Oncogênicas p21(ras)/genética , Fenótipo , Linhagem Celular , Mutação , Sequenciamento de Nucleotídeos em Larga Escala
5.
Electrophoresis ; 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38576224

RESUMO

This research focuses on the development and validation of a capillary electrophoresis (CE) method for the chiral separation of three H1-antihistamine drugs chlorcyclizine, norchlorcyclizine, and neobenodine using sulfated ß-cyclodextrin (S-ß-CD) as the chiral selector. The study explores various factors influencing the separation efficiency, including CD concentration, organic modifier content, voltage application, and buffer pH. Optimal conditions were identified as a 100 mM phosphate buffer (pH 6.0) with 34 mg mL-1 S-ß-CD and 40% (v/v) methanol. The method demonstrated excellent linearity in calibration curves, with coefficients of determination exceeding 0.99 for each enantiomer. Precision studies revealed good intra- and inter-day precision for migration times and peak areas. The limits of detection and quantification for the analytes were within the ranges of 5.9-11.4 and 18-34.6 µmol L-1, respectively. Overall, the developed CE method offers a robust and precise approach for the chiral separation of H1-antihistamine drugs, holding promise for pharmaceutical applications.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38578378

RESUMO

Nanoparticles (NPs) engineered as drug delivery systems continue to make breakthroughs as they offer numerous advantages over free therapeutics. However, the poor understanding of the interplay between the NPs and biomolecules, especially blood proteins, obstructs NP translation to clinics. Nano-bio interactions determine the NPs' in vivo fate, efficacy and immunotoxicity, potentially altering protein function. To fulfill the growing need to investigate nano-bio interactions, this study provides a systematic understanding of two key aspects: (i) protein corona (PC) formation and (ii) NP-induced modifications on protein's structure and stability. A methodology was developed by combining orthogonal techniques to analyze both quantitative and qualitative aspects of nano-bio interactions, using human serum albumin (HSA) as a model protein. Protein quantification via liquid chromatography-mass spectrometry, and capillary zone electrophoresis (CZE) clarified adsorbed protein quantity and stability. CZE further unveiled qualitative insights into HSA forms (native, glycated HSA and cysteinylated), while synchrotron radiation circular dichroism enabled analyzing HSA's secondary structure and thermal stability. Comparative investigations of NP cores (organic vs. hybrid), and shells (with or without polyethylene glycol (PEG)) revealed pivotal factors influencing nano-bio interactions. Polymeric NPs based on poly(lactic-co-glycolic acid) (PLGA) and hybrid NPs based on metal-organic frameworks (nanoMOFs) presented distinct HSA adsorption profiles. PLGA NPs had protein-repelling properties while inducing structural modifications on HSA. In contrast, HSA exhibited a high affinity for nanoMOFs forming a PC altering thereby the protein structure. A shielding effect was gained through PEGylation for both types of NPs, avoiding the PC formation as well as the alteration of unbound HSA structure.

7.
Talanta ; 274: 126016, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38599118

RESUMO

The present study investigates the use of dextrins (maltodextrin, ß-cyclodextrin, and hydroxypropyl-ß-cyclodextrin) to improve the efficiency of the agarose-based gel electromembrane extraction technique for extracting chiral basic drugs (citalopram, hydroxyzine, and cetirizine). Additionally, it examines the enantioselectivity of the extraction process for these drugs. To achieve these, dextrins were incorporated into either the sample solution, the membrane, or the acceptor solution, and then the extraction procedure was performed. Enantiomers were separated and analyzed using a capillary electrophoresis device equipped with a UV detector. The results obtained under the optimal extraction conditions (sample solution pH: 4.0, acceptor solution pH: 2.0, gel membrane pH: 3.0, agarose concentration: 3 % w/v, stirring rate: 1000 rpm, gel thickness: 4.4 mm, extraction voltage: 62.3 V, and extraction time: 32.1 min) indicated that incorporating dextrins into either the sample solution, membrane or the acceptor solution enhances extraction efficiency by 17.3-23.1 %. The most significant increase was observed when hydroxypropyl-ß-cyclodextrin was added to the acceptor solution. The findings indicated that the inclusion of hydroxypropyl-ß-cyclodextrin in the sample solution resulted in an enantioselective extraction, yielding an enantiomeric excess of 6.42-7.14 %. The proposed method showed a linear range of 5.0-2000 ng/mL for enantiomers of model drugs. The limit of detection and limit of quantification for all enantiomers were found to be < 4.5 ng/mL and <15.0 ng/mL, respectively. Intra- and inter-day RSDs (n = 4) were less than 10.8 %, and the relative errors were less than 3.2 % for all the enantiomers. Finally, the developed method was successfully applied to determine concentrations of enantiomers in a urine sample with relative recoveries of 96.8-99.2 %, indicating good reliability of the developed method.

8.
Anal Bioanal Chem ; 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38594392

RESUMO

Messenger RNA (mRNA) vaccines represent a landmark in vaccinology, especially with their success in COVID-19 vaccines, which have shown great promise for future vaccine development and disease prevention. As a platform technology, synthetic mRNA can be produced with high fidelity using in vitro transcription (IVT). Magnesium plays a vital role in the IVT process, facilitating the phosphodiester bond formation between adjacent nucleotides and ensuring accurate transcription to produce high-quality mRNA. The development of the IVT process has prompted key inquiries about in-process characterization of magnesium ion (Mg++) consumption, relating to the RNA polymerase (RNAP) activation, fed-batch mode production yield, and mRNA quality. Hence, it becomes crucial to monitor the free Mg++ concentration throughout the IVT process. However, no free Mg++ analysis method has been reported for complex IVT reactions. Here we report a robust capillary zone electrophoresis (CZE) method with indirect UV detection. The assay allows accurate quantitation of free Mg++ for the complex IVT reaction where it is essential to preserve IVT samples in their native-like state during analysis to avoid dissociation of bound Mg complexes. By applying this CZE method, the relationships between free Mg++ concentration, the mRNA yield, and dsRNA impurity level were investigated. Such mechanistic understanding facilitates informed decisions regarding the quantity and timing of feeding starting materials to increase the yield. Furthermore, this approach can serve as a platform method for analyzing the free Mg++ in complex sample matrices where preserving the native-like state of Mg++ binding is key for accurate quantitation.

9.
J Med Eng Technol ; : 1-5, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38588474

RESUMO

Electrophoretic tissue clearing has been a commonly used laboratory method since the early twentieth century. Infrastructure for standard procedures has yet to be formed. In particular, control of the heat produced by electrophoresis, the voltage applied to the electrodes, the resistance, and the speed of liquid circulation create difficulty for researchers. We aimed to develop a compact organ electrophoresis system that enables the researcher to have easy, rapid, and inexpensive working opportunities. The system includes an electronic control unit, a liquid tank, a temperature control unit, and an electrophoresis chamber. The control unit software can keep the system stable by using information on temperature and circulation rate received through the sensors using the feedback principle. Corrosion and particle collection are reduced to a minimum as platinum wires are used for electrophoresis electrodes. A temperature control unit can heat and cool via a liquid tank base. The CORES is an all-in-one, easy-to-use solution for electrophoretic tissue clearing. It assures efficient, rapid, and consistent tissue clearing. The system was stable with 72 h of continuous operation. Patent applications and trial version studies for introducing the system to researchers are still in progress.

10.
Se Pu ; 42(4): 327-332, 2024 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-38566421

RESUMO

The physical and chemical properties of chiral drugs are very similar. However, their pharmacological and toxicological effects vary significantly. For example, one enantiomer may have favorable properties whereas the other may be ineffective or even have toxic side effects. Hence, exploring innovative strategies to improve enantiomeric resolution is of great importance. Metoprolol (MET) is a ß-receptor blocker used to treat hypertension, stable angina pectoris, and supraventricular tachyarrhythmia. Establishing chiral separation and analysis methods of MET enantiomers is important for enhancing the quality of chiral drugs. Capillary electrophoresis (CE) has the advantages of a small sample size, simple operation, high separation efficiency, and many alternative modes; therefore it is widely used in the field of chiral drug separation. The chiral selectors commonly used for CE-based chiral separation include cyclodextrin (CD) and its derivatives, polysaccharides, proteins, and macrocyclic antibiotics. CD is one of the most commonly used and effective chiral selectors for CE. The relatively hydrophobic structure inside the cavity and the relatively hydrophilic structure outside the cavity of CD enable it and chiral molecules to form inclusion compounds with different binding constants, thus achieving chiral separation. However, the use of CD alone as a chiral selector does not always yield satisfactory separation results. Hence, the addition of other additives, such as ionic liquids and deep eutectic solvents (DESs) to assist CD-based chiral separation systems has received extensive attention. Previous studies on the enantiomeric separation of MET by CE have focused on the addition of CD and its derivatives alone for separation. Few studies have been conducted on the synergistic addition of auxiliary additives to CD to improve the enantiomeric resolution of MET. In this study, three DESs, namely, choline chloride-D-glucose, choline chloride-D-fructose, and lactate-D-glucose, were used for the CE-based chiral separation of MET for the first time, and the synergistic effect of the DESs on the separation of MET enantiomers by CD-based capillary zone electrophoresis was speculated. For this purpose, an uncoated fused silica capillary with inner diameter of 50 µm, total length of 50 cm and effective length of 41.5 cm was used as the separation column. First, the effects of CD type, CD concentration, buffer pH, and buffer concentration on MET separation were investigated, and the optimal conditions (15 mmol/L carboxymethyl-ß-cyclodextrin (CM-ß-CD), pH=3.0, and 40 mmol/L phosphate buffer) were obtained. Other CE conditions were as follows: UV detection at 230 nm, applied voltage of 25 kV. All operations were carried out at 20 ℃. Next, three types of DESs were prepared as auxiliary additives via a mixed-heating method. The DESs were mixed in a 50 mL round-bottomed flask at a certain molar ratio and then heated in a water bath at 80 ℃ for 3 h until a clear and transparent liquid was obtained. The effects of different DESs and their mass fraction on chiral separation were subsequently studied. The optimal choline chloride-D-fructose mass fraction was ultimately determined to be 1.5%. The resolution of MET increased from 1.30 without DES to 2.61 with 1.5% choline chloride-D-fructose, thereby achieving baseline separation. Finally, the separation effect and mechanism were speculated. The MET chiral separation method established in this study is of great significance for improving the quality of chiral compounds and ensuring the safety and effectiveness of clinical drugs. Furthermore, it may be useful in the research and development of CE-based chiral separation techniques using CD derivatives with DESs.


Assuntos
Ciclodextrinas , beta-Ciclodextrinas , Metoprolol , Solventes Eutéticos Profundos , beta-Ciclodextrinas/química , Eletroforese Capilar/métodos , Colina , Frutose , Glucose , Estereoisomerismo
11.
Mol Cell Probes ; 75: 101960, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38583643

RESUMO

Variable Fragment Length Allele-Specific Polymerase Chain Reaction (VFLASP) and Amplification Refractory Mutation System (ARMS) are reliable methods for detecting allelic variations resulting from single base changes within the genome. Due to their widespread application, allele variations caused by Single Nucleotide Polymorphisms (SNPs) can be readily detected using allele-specific primers. In the context of the current study, VFLASP was combined with ARMS method as a novel strategy to enhance the efficacy of both techniques. Clinically important base variations within SNP regions used in the study were detected by a fragment analysis method. To validate the accuracy of the developed VFLASP-ARMS method, specifically designed synthetic sequences were tested using a capillary electrophoresis system. Allele-specific primers exhibit differences solely at the 3' end based on the sequence of the SNP. Additionally, to increase the specificity of the primers, a base was intentionally added for incompatibility. Therefore, allele discrimination on fragment analysis has been made possible through the 3-6 bp differences in the amplicons. With the optimization of the system, designed synthetic sequences provided reliable and reproducible results in wild-type, heterozygous, and homozygous genotypes using the VFLASP-ARMS method. Hence, our results demonstrated that VFLASP-ARMS method, offers a novel design methodology that can be included in the content of SNP genotyping assays.

12.
Artigo em Inglês | MEDLINE | ID: mdl-38627346

RESUMO

Electrochemical desalination is an effective method for recovering salts from reverse osmosis (RO) brine. However, traditional technologies like bipolar membrane technology often face challenges related to membrane blockage. To overcome this issue, a preparative vertical-flow electrophoresis (PVFE) system was used for the first time to treat RO brine of petrochemical wastewater. In order to optimize the PVFE operation and maximize acids and bases production while minimizing energy consumption, the response surface method was employed. The independent variables selected were the electric field intensity (E) and flow rate (v), while the dependent variables were the acid-base concentration and energy consumption (EC) for acid-base production. Using the central composite design methodology, the operation parameters were optimized to be E = 154.311 V/m and v = 0.83 mL/min. Under these conditions, the base concentrations of the produced bases and acids reached 3183.06 and 2231.63 mg/L, respectively. The corresponding base EC and acid EC were calculated to be 12.57 and 11.62 kW·h/kg. In terms of the acid-base concentration and energy consumption during the PVFE process, the electric field intensity was found to have a greater influence than the flow rate. These findings provide a practical and targeted solution for recycling waste salt resources from RO brine.

13.
Electrophoresis ; 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38571381

RESUMO

The recent rise in nucleic acid-based vaccines and therapies has resulted in an increased demand for plasmid DNA (pDNA). As a result, there is added pressure to streamline the manufacturing of these vectors, particularly their design and construction, which is currently considered a bottleneck. A significant challenge in optimizing pDNA production is the lack of high-throughput and rapid analytical methods to support the numerous samples produced during the iterative plasmid construction step and for batch-to-batch purity monitoring. pDNA is generally present as one of three isoforms: supercoiled, linear, or open circular. Depending on the ultimate use, the desired isoform may be supercoiled in the initial stages for cell transfection or linear in the case of mRNA synthesis. Here, we present a high-throughput microfluidic electrophoresis method capable of detecting the three pDNA isoforms and determining the size and concentration of the predominant supercoiled and linear isoforms from 2 to 7 kb. The limit of detection of the method is 0.1 ng/µL for the supercoiled and linear isoforms and 0.5 ng/µL for the open circular isoform, with a maximum loading capacity of 10-15 ng/µL. The turnaround time is 1 min/sample, and the volume requirement is 10 µL, making the method suitable for process optimization and batch-to-batch analysis. The results presented in this study will enhance the understanding of electrophoretic transport in microscale systems dependent on molecular conformations and potentially aid technological advances in diverse areas relevant to microfluidic devices.

14.
J Proteome Res ; 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38572994

RESUMO

The delay in making a correct diagnosis of Candida auris causes concern in the healthcare system setting, and immunoproteomics studies are important to identify immunoreactive proteins for new diagnostic strategies. In this study, immunocompetent murine systemic infections caused by non-aggregative and aggregative phenotypes of C. auris and by Candida albicans and Candida haemulonii were carried out, and the obtained sera were used to study their immunoreactivity against C. auris proteins. The results showed higher virulence, in terms of infection signs, weight loss, and histopathological damage, of the non-aggregative isolate. Moreover, C. auris was less virulent than C. albicans but more than C. haemulonii. Regarding the immunoproteomics study, 13 spots recognized by sera from mice infected with both C. auris phenotypes and analyzed by mass spectrometry corresponded to enolase, phosphoglycerate kinase, glyceraldehyde-3-phosphate dehydrogenase, and phosphoglycerate mutase. These four proteins were also recognized by sera obtained from human patients with disseminated C. auris infection but not by sera obtained from mice infected with C. albicans or Aspergillus fumigatus. Spot identification data are available via ProteomeXchange with the identifier PXD049077. In conclusion, this study showed that the identified proteins could be potential candidates to be studied as new diagnostic or even therapeutic targets for C. auris.

15.
J Parkinsons Dis ; 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38578903

RESUMO

Background: Alpha-synuclein (aSyn) is a key player in neurodegenerative diseases such as Parkinson's disease (PD), dementia with Lewy bodies, or multiple system atrophy. aSyn is expressed throughout the brain, and can also be detected in various peripheral tissues. In fact, initial symptoms of PD are non-motoric and include autonomic dysfunction, suggesting that the periphery might play an important role in early development of the disease. aSyn is expressed at relatively low levels in non-central tissues, which brings challenges for its detection and quantification in different tissues. Objective: Our goal was to assess the sensitivity of aSyn detection in central and peripheral mouse tissues through capillary electrophoresis (CE) immunoblot, considering the traditional SDS-PAGE immunoblot as the current standard. Methods: Tissues from central and non-central origin from wild type mice were extracted, and included midbrain, inner ear, and esophagus/stomach. aSyn detection was assessed through immunoblotting using Simple Western size-based CE and SDS-PAGE. Results: CE immunoblots show a consistent detection of aSyn in central and peripheral tissues. Through SDS-PAGE, immunoblots revealed a reliable signal corresponding to aSyn, particularly following membrane fixation. Conclusion: Our results suggest a reliable detection of aSyn in central and peripheral tissues using the CE Simple Western immunoblot system. These observations can serve as preliminary datasets when aiming to formally compare CE with SDS-PAGE, as well as for further characterization of aSyn using this technique.

16.
J Chromatogr A ; 1722: 464853, 2024 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-38579611

RESUMO

This study presents a methodology for designing effective insulator-based electrokinetic (iEK) systems for separating tertiary microparticle samples, which can be extended to more complex samples. First, 144 distinct iEK microchannel designs were built considering different shapes and arrangements of the insulating posts. Second, a mathematical model was developed with COMSOL software to predict the retention time of each particle type in the microchannel, this allowed identifying the best channel designs for two distinct types of separations: charge-based and sized-based. Third, the experimental charge-based and size-based separations of the tertiary microparticle mixtures were performed employing the improved designs identified with COMSOL modeling. The experimental results demonstrated successful separation in terms of separation resolution and good agreement with COMSOL predictions. The findings from this study show that the proposed method for device design, which combines mathematical modeling with varying post shape and post arrangement is an effective approach for identifying iEK systems capable of separating complex microparticle samples.

17.
Int J Biol Macromol ; 266(Pt 2): 131339, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38574925

RESUMO

The AcPase exhibits a specific activity of 31.32 U/mg of protein with a 728-fold purification, and the yield of the enzyme is raised to 3.15 %. The Zn2+-dependent AcPase showed a purification factor of 1.34 specific activity of 14 U/mg of proteins and a total recovery of 5.14. The SDS-PAGE showed a single band corresponding to a molecular weight of 18 kDa of AcPase and 29 kDa of Zn2+-dependent AcPase. The AcPase enzyme has shown a wide range of substrate specificity for p-NPP, phenyl phosphate and FMN, while in the case of ZnAcPase α and ß-Naphthyl phosphate and p-NPP were proved to be superior substrates. The divalent metal ions like Mg2+, Mn2+, and Ca2+ increased the activity, while other substrates decreased the enzyme activity. The Km (0.14 mM) and Vmax (21 µmol/min/mg) values of AcPase were higher than those of Zn2+-AcPase (Km = 0.5 mM; Vmax = 9.7 µmol/min/mg). The Zn2+ ions activate the Zn2+-AcPase while Fe3+, Al3+, Pb2+, and Hg2+ showed inhibition on enzyme activity. Molybdate, vanadate and phosphate were found to be competitive inhibitors of AcPase with Ki values 316 µM, 185 µM, and 1.6 mM, while in Zn2+-AcPase tartrate and phosphate also showed competitive inhibition with Ki values 3 mM and 0.5 mM respectively.

18.
Anal Bioanal Chem ; 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38581532

RESUMO

This paper describes the use of PolyJet 3D printing to fabricate microchip electrophoresis devices with integrated microwire electrodes for amperometric detection. The fabrication process involves 3D printing of two separate pieces, a channel layer and an electrode layer. The channel layer is created by 3D printing on a pre-fabricated mold with a T-intersection. For the electrode layer, a stencil design is printed directly on the printing tray and covered with a piece of transparent glass. Microwire electrodes are adhered over the glass piece (guided by underlaying stencil) and a CAD design of the electrode layer is then printed on top of the microwire electrode. After delamination from the glass after printing, the microwire is embedded in the printed piece, with the stencil design ensuring that alignment and positioning of the electrode is reproducible for each print. After a thermal bonding step between the channel layer and electrode layer, a complete electrophoresis device with integrated microelectrodes for amperometric detection results. It is shown that this approach enables different microwire electrodes (gold or platinum) and sizes (100 or 50 µm) to be integrated in an end-channel configuration with no gap between the electrode and the separation channel. These devices were used to separate a mixture of catecholamines and the effect of separation voltage on the potential voltage applied on the working electrode was also investigated. In addition, the effect of electrode size on the number of theoretical plates and limit of detection was studied. Finally, a device that contains different channel heights and a detection electrode was 3D-printed to integrate continuous flow sampling with microchip electrophoresis and amperometric detection.

19.
Transfus Apher Sci ; : 103919, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38582651

RESUMO

Delayed hemolytic transfusion reaction (DHTR) and hyperhemolysis syndrome (HHS) are both complications of red blood cell transfusions in patients with sickle cell disease.Clinically, both present with hemolysis and can be difficult to differentiate. Hemoglobin electrophoresis may aid in the diagnosis. Herein we describe a case in which a patient with hemoglobin SC disease presented with features of severe hemolysis several days after initiation of red blood cell exchange. Increase in reticulocyte count and complete absence of hemoglobin A on electrophoresis during this event supported the diagnosis of severe DHTR, indicating a rapid and selective destruction of the transfused red blood cells. Ability to interpret the hemoglobin electrophoresis can help clinicians distinguish between these two severe transfusion complications in patients living with sickle cell disease. It is important to identify the presence or absence of concomitant HHS, as patients with HHS tend to have a worse prognosis and there is a higher rate of recurrence of HHS with subsequent transfusions. Accurate diagnosis can lead to prompt management and decrease morbidity and mortality.

20.
Molecules ; 29(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38611879

RESUMO

Enhancing the pH-independence and controlling the magnitude of electroosmotic flow (EOF) are critical for highly efficient and reproducible capillary electrophoresis (CE) separations. Herein, we present a novel capillary modification method utilizing sulfonated periodate-induced polydopamine (SPD) coating to achieve pH-independent and highly reproducible cathodic EOF in CE. The SPD-coated capillaries were obtained through post-sulfonation treatment of periodate-induced PDA (PDA-SP) coatings adhered on the capillary inner surface. The successful immobilization of the SPD coating and the substantial grafting of sulfonic acid groups were confirmed by a series of characterization techniques. The excellent capability of PDA-SP@capillary in masking silanol groups and maintaining a highly robust EOF mobility was verified. Additionally, the parameters of sulfonation affecting the EOF mobilities were thoroughly examined. The obtained optimum SPD-coated column offered the anticipated highly pH-independent and high-strength cathodic EOF, which is essential for enhancing the CE separation performance and improving analysis efficiency. Consequently, the developed SPD-coated capillaries enabled successful high-efficiency separation of aromatic acids and nucleosides and rapid cyclodextrin-based chiral analysis of racemic drugs. Moreover, the SPD-coated columns exhibited a long lifetime and demonstrated good intra-day, inter-day, and column-to-column repeatability.